6.4 Engraving Machine Macro 400HZ
6.4 Engraving Machine Macro 400HZ
X1 controls forward rotation start/stop, X2 controls multi-speed terminal 1, X3 controls multi-speed terminal 2, X4 controls multi-speed terminal 3. The combination of three terminals is as follows:
| Speed | Corresponding Frequency | Multi-Speed Terminal 1 | Multi-Speed Terminal 2 | Multi-Speed Terminal 3 |
|---|---|---|---|---|
| 0 | 0Hz | OFF | OFF | OFF |
| 1 | 100Hz | ON | OFF | OFF |
| 2 | 150Hz | OFF | ON | OFF |
| 3 | 200Hz | ON | ON | OFF |
| 4 | 250Hz | OFF | OFF | ON |
| 5 | 300Hz | ON | OFF | ON |
| 6 | 350Hz | OFF | ON | ON |
| 7 | 400Hz | ON | ON | ON |